- PROFINET Certification
- Eight Port IO-Link Master to PROFINET IO
- Rugged IP67 housing desing for harsh environments, M12 connectors allowing up to eight sensor or actuator connections on one master block
- PROFINET IO access to IO-Link process, event and service data
- PLC access to IO-Link ISDU blocks without complex programming
- Supports the IOL_CALL function module
- GDSML files
- Power port sharing capability
- Powerful web GUI for configuration and diagnostics, including:
- IO-Link device management using the IO-Link device manufacturers IODD file for easy device configuration
- Automatic data storage (upload and download)
- Manual data storage (upload and download)
- Device validation
- Data validation
- Wide operating temperature (-25° to +60°C)
- Additional digital input on every port
- IO-Link V1.0 and V1.1 compatibility
- IO-Link COM1, COM2 and COM3 (230K baud rate) support
- Quality of Serices Agreement
- Accredited IO-Link Test Center
IO-Link Master common configuration networking diagram
Comtrol’s IO-Link Master combines the benefits of the IO-Link standard with the EtherNet/IP™ and Modbus TCP protocols. The IO-Link Master effectively shields the PLC programmers from the IO-Link complexities by handling those complexities itself. The result is simplified EtherNet/IP™ and Modbus TCP interfaces,which decreases system development time and installation efforts.
The IO-Link Master features a rugged IP67 slim-line design incorporating two Fast Ethernet ports and eight IO-Link ports with M12 connectors. Designed for harsh environments, its machine-mount design uses industrial grade components. The IO-Link Master is easily integrated into a system network, and is compatible with existing and new industrial Ethernet installations.
- IO-Link Master 8-PNIO
- Quick Start card
- Network Interface 10/100BASE-TX
- EnclosureMolded ABS (potted)
- Ingress Protection Rating IP67
- Installation and Grounding MethodMachine or panel mount
Two-hole M4 or #8 screws - Network ProtocolsPROFINET IO
- Connectors (M12)8 - IO-Link
2 - Ethernet
2 - Power - LED IndicatorsPower, Module Status, Network Status, IO-Link, DI and Ethernet Port Status
- Dimensions 8.35" x 2.56" x 1.18"
212 x 65 x 30 mm - Product Weight 1.0 lb
454 kg
- Connector TypeFemale, M12, A-coded, 5-pin
- Number of Ports8
- IO-Link Version Support V1.0 and V1.1
- Connector Pinout Pin 1 = L+
Pin 2 = DI
Pin 3 = L-
Pin 4 = C/Q
Pin 5 = Not Connected
- Configurations per Port IO-Link = 1
DI (SIO mode) = 1
DO (SIO mode) = 1
DI (dedicated) = 1 - IO-Link Mode Transfer Rates4.8K (COM1)
38.4K (COM2)
230.4K (COM3) - Baud Rate RecognitionAutomatic
-
Output Current on IO-Link Connectors (Ports 1-8)
- C/Q on Pin 4Vs on Pins 1, 3
- 200mA (Maximum)1.6A (Maximum)
- 200mA (Maximum)500mA (Maximum)
- Short Circuit ProtectionYes
- Cable Length (Maximum)20 m
- Sensor Current Load (Maximum)200mA
- Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
- Short-Circuit and Overload protectionYes
- Short-Circuit proof Yes
- Input Current LimitationYes
- C/Q Input ThresholdLow: 8.0 - 11.5V
High: 10.5 - 13.0V
- Actuator Current Load (Maximum)200mA
- Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
- Short-Circuit and Overload ProtectionYes
- Short-Circuit proofYes
- Input Current LimitationYes
- Output FunctionPNP/NPN
- Sensor Current Load (Maximum)200mA
- Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
- Short-Circuit and Overload protectionYes
- Short-Circuit proof Yes
- Input Current LimitationYes
- DI Input ThresholdLow: 5.2 - 6.4V
High: 6.8 - 8.0V
- Web Page ConfigurationPROFINET IO Device Name
IOL_CALL Function Block Timeout (1-20) - Diagnostics Yes
- GSD FilesYes
- Data StorageAutomatic or Manual - Upload and/or Download
- Device Validation Yes
- Data ValidationYes
- Powerful Web InterfaceProvides the following capabilities:
• Firmware upgradable
• Password protected with Admin, Operator, and User accounts
• ISDU batch handling
• Load IODD files to configure the IO-Link device
• IODD Handler parses xml files making them readable and configurable
• Log files - Upgradable Firmware Yes (Web page or using PortVision DX)
- Remote ParameterizationYes
- Mobile App SupportSimplify monitoring of control system Process and Service Data using simple standard clients available for free in Google Play and Apple App Store
- Input Voltage Range20-30VDC / 12A (Maximum)
-
Power Supply In
- Vs12A (Maximum)
- Va10A (Maximum)
- Power Consumption (Without Load)100mA @ 24VDC (Vs)
-
Power Supply Out
- Vs12A (Maximum)*
- Va10A (Maximum)**
- *Vs output available is determined by subtracting the following from the available input current:
- • IO-Link module power
- • Actual C/Q current for each IO-Link port (w/out devices)
- • Actual Vs current for each IO-Link port
- *Va output available is the same as the available Va input current
- Short Circuit Protection for IO-Link ConnectorsYes
-
Power Connectors
- Input (1)Male, M12 T-coded, 5-pin
- Output (2)Female, M12 T-coded, 5-pin
-
Air Temperature
- System On -25°C to +60°C
- System Off -40°C to +70°C*
- Operating Humidity (non-condensing)10% to 95%
- Storage Humidity (non-condensing)10% to 95%
- Shock/VibrationsEN60068-2-6
EN60068-2-27 - Enclosure RatingIP67 (IEC 60529)
- Packaged Shipping Weight1.2 lb
544.3 kg - Package Dimensions (L x W x H)10.5" x 4.5" x 1.5"
266.7 x 114.3 x 38.1mm - UPC Code7-56727-99605-7
- Country of OriginUSA
- ECCN5A992
- Schedule B Number8517.62.0050
- ImmunityEuropean Standard EN 61000-6-2
IEC/EN 61131-2
IEC 1000-4-2/EN 61000-4-2: Electrostatic Discharge (ESD)
IEC 1000-4-3/EN 61000-4-3: Radiated, Radio-Frequency (RF)
IEC 1000-4-4/EN 61000-4-4: Fast Transient/Burst
IEC 1000-4-5/EN 61000-4-5: Surge
IEC 1000-4-6/EN 61000-4-6: Conducted disturbance
IEC 1000-4-8/EN 61000-4-8: Magnetic field
IEC 1000-4-11/EN 61000-4-11: Dips and Voltage Variations - EmissionsEuropean Standard EN 61000-6-4
AS/NZS CISPR-22
FCC Part15 Subpart B
Class A limit
Canadian EMC requirements ICES-003 - SafetyCSA C22.2 No. 142/UL 508E360395
- OtherIngress Protection rating IP67 (IEC 60529)
Environmental & Mechanical testing pre IEC/EN 61131-2
Europeal Standard: 2011/65/EU (RoHS2) Directive. - Regulatory Approval Symbols
» Industrial Distributors
» North American Distributors
» International Distributors
Comtrol's Pre-sales Team
For sales questions or to locate a reseller near you.
+1-800-926-6876 (1-800-Go Rocket)
+1-763-957-6000
Fax: +1-763-957-6001
sales@comtrol.com
Comtrol's Industrial Automation Sales
For sales questions or to locate an industrial distributor near you.
+1-800-926-6876 (1-800-Go Rocket)
+1-763-957-6000
Fax: +1-763-957-6001
sales@comtrol.com
Document | Description | Download File |
---|---|---|
IO-Link Master 8-PNIO User Guide | Contains detailed installation procedures and configuration information. |
Call +1.763.957.6000, or e-mail sales@comtrol.com
For technical assistance, our U.S.-based technical support team is only a phone call away.
Call +1.763.957.6000, or submit your question online, or visit our forum .